Check list before the test may begin

  • To achieve a fair test result it is vital that the building envelope is complete. This includes external doors, all glazing plus frames sealed and cladding completed.

 

  • Any forms of loft hatches should be finished and ideally have a draft excluder

  • All light fixtures and socket fixtures to be fitted 

  • Window frames to be sealed between the external walls i.e. silcone/expanding foam

  • SVP pipes or any types of pipes exiting the envelope area should be well sealed

  • All plumbing installed and all traps/U bends to have water in

  • Skirting boards to be fixed and sealed

  • Also noted that chimneys should be checked before we arrive on site to make sure they are properly sealed and that any flues that have been installed are not leaking.

  • Please be aware that testing cannot take place in high wind conditions

  • Upon our visit we will temporay seal extractor fans and possibly trickle vents depending on when the dwelling was constructed.

  • It should be noted that to do the test we will require 240v or 110v power , if this is a problem please contact us before our visit.